An electrical panel is not safe just because good components go into it; it must be correctly designed and verified as a whole. We summarise what IEC 61439 covers and what to look for when buying a panel.
When buying an electrical panel, the first thing people often look at is the brand of breakers inside. Yet putting quality components together does not by itself make a panel safe. How the components affect each other inside the same enclosure, how heat is dissipated and how busbars and connections behave during a short circuit are properties of the panel as a whole. This is exactly what the IEC 61439 standard addresses.
What is IEC 61439?
IEC 61439 is the international series of standards covering low-voltage switchgear and controlgear assemblies, in everyday language low-voltage panels. Part 1 of the series (IEC 61439-1) sets out the general rules, and Part 2 (IEC 61439-2) covers power switchgear and controlgear assemblies. There are further parts for other types of panels, such as distribution boards.
The core approach of the standard is that a panel is treated as a product in its own right, not as the sum of its components. The design of the panel must therefore be verified for certain characteristics.
What does design verification cover?
IEC 61439 requires the panel design to be verified by methods such as testing, calculation or comparison with a reference design. The main characteristics verified are:
- Temperature rise: When the panel operates at full load, the internal temperature must stay within the limits the components and insulating materials can withstand.
- Short-circuit withstand: Busbars, connections and supports must withstand the high currents and forces produced during a short circuit.
- Insulation and dielectric properties: Clearances and insulating materials must be suitable for the voltage.
- Continuity of the protective circuit: Enclosure and earthing connections must ensure that the protective conductor keeps working in the event of a fault.
- Mechanical strength and degree of protection: The enclosure must be strong enough and its IP rating suitable for the installation environment.
In addition to design verification, routine verification is carried out on every panel produced. At this stage, items such as tightness of connections, wiring, the protective circuit, insulation and functional checks are reviewed.
Why does the IP rating matter?
The IP code shows how well the panel is protected against solid objects and water. The first digit refers to protection against dust and solid objects, the second to protection against water. A panel in a closed, dry electrical room does not have the same needs as one outdoors, in an irrigation area or in a plant room by the sea. The right IP rating has a direct effect on the panel’s service life and safety.
What should you look for when buying a panel?
- Project-specific design: Ask whether the panel is designed for the connected loads, the short-circuit level and the installation environment.
- Documentation: Single-line diagrams and layout drawings are needed for future maintenance and expansion.
- Labelling: Clear labelling of outgoing circuits and components saves time when a fault occurs.
- Room for expansion: Space and capacity left for loads that may be added later.
- The manufacturer’s quality system: Running production within a defined quality management system ensures every panel is built with the same care.
The Aynalı PLC & Otomasyon approach
We continue the experience that began in 1973 under the name Teknik Elektrik with the electrical assembly of low- and medium-voltage panels, now as Aynalı PLC & Otomasyon. We manufacture our panels in line with IEC 61439-1&2 within an ISO 9001:2015 quality management system. We design for each project individually and continuously improve our processes based on customer feedback. Contact us for a standards-compliant panel solution for your project.